Loading... Please wait...

FastLay Universal 7

Residential R-Values

Total R Values (m2.KW)

BCA thermal break .20- Complies
AS/NZ 4859.1/ 2006 - Complies
AS 4200.1- Complies
Heat Flow Out (winter)Heat Flow In (summer)

TILED ROOF - PITCHED

Calc No. 365r04

R5.5 R5.8
  FastLay Universal 7 - Pitched tiled roof(22.5deg pitch), Unventilated 60mm sealed semi-reflective air gap, FastLay Universal 7 + R4.0 bulk insulation, 10mm plasterboard

METAL ROOF - PITCHED

Calc No. 365r03

R5.8 R6.4
  FastLay Universal 7 - Pitched metal roof(22.5deg pitch), Unventilated 60mm sealed semi-reflective air gap, FastLay Universal 7 + R4.0 bulk insulation, 10mm plasterboard

UNDERFLOOR - TIMBER

Calc No. 365f01

R3.4 R1.7
  FastLay Universal 7 - Timber floor, 19mm 90mm sealed semi-reflective air gap, FastLay Universal 7 reflective insulation, unventilated reflective

BRICK VENEER WALL

Calc No. 365w02

R3.8 R3.6
  FastLay Universal 7 - 110mm brickwork, 43mm semi-reflective air gap, FastLay Universal 7 reflective insulation, 25mm reflective air gap, R1.5 bulk insulation (65mm 12kg/m3), 10mm plasterboard

WEATHERBOARD WALL

Calc No. 365w01

R3.7 R3.4
  FastLay Universal VP 7 (Vapour Permeable) - Pine weatherboards, 25mm semi-reflective air gap, FastLay Universal 7 reflective insulation, 25mm air, R1.5 builk insulation (65mm 12kg/m3), 10mm plasterboard

Commercial R-Values

 BCA -  Complies
AS/NZ 4859.1/ 2006 - Complies
AS 4200.1- Complies
Heat Flow In (summer)Heat Flow Out (winter)

WAREHOUSE ROOF WITH FASTLAY UNIVERSAL 7

CALC NO. 365r01

R2.2

R1.0

 

Flat metal roof (1 to 5 degree pitch) , 60mm sealed semi reflective still air gap,FastLay Universal 7 reflective insulation, wire mesh support

   

OFFICE ROOF WITH FASTLAY UNIVERSAL 7

Calc No. 365r02

R3.5 R1.7
  Flat metal roof (1 to 5 degree pitch), 60mm sealed semi reflective still air gap, FastLay Universal 7 reflective insulation 100+mm reflective still air space, suspended grid acoustic ceiling    
  • The Total R-value calculations are in accordance with AS/NZS 4859.1:2002/Amdt1:2006, and are based on a temperature difference between indoor and outdoor air temperatures of 6°C for winter and 12°C for summer.
  • The contribution of Fastlay universal 7 Insulation Pty Ltd to Total R-value depends on installation and environmental conditions.
  • The R-value will be reduced in the event of the accumulation of dust on upward facing surfaces and in those cavities that are ventilated.